LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
QS90SR2SP-CC | MITSUBISHI Safety relay module QS90SR2SP-CC
MITSUBISHI QS90SR2SP-CC Manual And Instructions
QS90SR2SP-CC datasheetPDF datasheet
QS90SR2SP-CC User's Manual
QS90SR2SP-CC Safety Application Guide
QS90SR2SP-CC Safety Guideline
QS90SR2SP-CC Safety Guideline

MITSUBISHI QS90SR2SP-CC Product information and technical parameters:
Brand: MITSUBISHI
Name: Safety relay module
Model: QS90SR2SP-CC
Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces.
Visualization of installation status.
Can monitor the safe output, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start.

The input and output module installation number: 4.
Could extend the connection: not to extend the connection.
Application module: QS series module.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI QS90SR2SP-CC.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards QS90SR2SP-CC
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures MITSUBISHI QS90SR2SP-CC.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down MITSUBISHI QS90SR2SP-CC. "Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL3.
Performance level: PLe.
PFHd:0.4E-091/h.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Control mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0.10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed ooutside the standard control procedures QS90SR2SP-CC.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down QS90SR2SP-CC.


...More relevant models >>>>