MITSUBISHI QS90SR2SN-EX Manual QS90SR2SN-EX Safety Guideline
Product model: QS90SR2SN-EX
Name: PLC
Brand: MITSUBISHI
Sort: Safety Guideline
File language: English
Program capacity: 8K step.
Input / output points: 1024 points.
Number of input and output elements: 2048.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password QS90SR2SN-EX Manual QS90SR2SN-EX Safety Guideline QS90SR2SN-EX
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time QS90SR2SN-EX Manual QS90SR2SN-EX Safety Guideline.
Continuous access file register.Extended SRAM card 4MB
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording QS90SR2SN-EX Manual QS90SR2SN-EX Safety Guideline. Redundant CPU data tracking cable length of 3 meters.
Can only be used for MITSUBISHI Q series PLC redundancy CPU.Input points: 16 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
16 point /1 a public side.
Common anode.
18 point terminal station.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direcct connection (1 to 1),
No need to carry out the IP address settings QS90SR2SN-EX Manual QS90SR2SN-EX Safety Guideline. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection QS90SR2SN-EX Manual QS90SR2SN-EX Safety Guideline.
Related products
MITSUBISHI
Safety relay module
QS90SR2SP-EX
MITSUBISHI Safety relay module QS90SR2SP-EX
Application: extension. Suitale for saf
MITSUBISHI
Safety relay module
QS90SR2SP-CC
MITSUBISHI Safety relay module QS90SR2SP-CC
Meet safety standards: EN954-1 class 4,
MITSUBISHI
Safety relay module
QS90SR2SN-Q
MITSUBISHI Safety relay module QS90SR2SN-Q
Application: Q series. Suitale for safe
MITSUBISHI
Safety relay module
QS90SR2SP-Q
MITSUBISHI Safety relay module QS90SR2SP-Q
Application: Q series. Suitale for safe