Application: Q series.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Add up to 3 additional units: safety relay module.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file.
Transmission speed: 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps (automatic tracking).
Station No.: 1~64 station.
External connection mode: 2 pieces of spring clip terminal.
Spring clip terminal.
The safety controller can communicate with the master station of the CCLINK system.
The data from the security controller to the master station can be edited by the parameters MITSUBISHI QS90SR2SN-Q.
The security controller receives the data from the master station to set the tag name
QS90SR2SN-Q
Transmission speed according to the automatic tracking station, do not need to set the transmission speed.
By using the spring clamping terminal, the wiring time and the maintenance time of the CC-Link cable can be reduced.
No need to re write parameters after replacement of the module MITSUBISHI QS90SR2SN-Q.
The security controller can be set up and connected with the monitoring software.
Confirm the error record that is detected. Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL3.
Performance level: PLe.
PFHd:0.4E-091/h.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure MITSUBISHI QS90SR2SN-Q.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Application: Q series.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Add up to 3 additional units: safety relay module.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure QS90SR2SN-Q.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connecttion settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file QS90SR2SN-Q.