Modular
A1SJ72J95


JEMANET (OPCN-1) interface unit from the station. The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
MITSUBISHI
Network module
A1SJ72QBR15


3C-2V/5C-2V coaxial cable single bus remote I/O network (remote I/O station). Q mode.
MITSUBISHI
Network module
A1SJ72QLP25


SI/QSI/H-PCF/ wide H-PCF optical cable dual layer remote I/O network (remote I/O station) Switch volume control is designed to, According to the current input combination of the switch quantity and the history of the input sequence, So that PLC generates the corresponding switching output, In order to make the system work in a certain order. So, sometimes also known as the order control.
MITSUBISHI
Network module
A1SJ72QLR25


3C-2V/5C-2V coaxial dual ring remote I/O network (remote I/O station). Q mode.
MITSUBISHI
Melsecnet remote interface module
A1SJ72T25B


By MELSECNET/B I/O can be decentralized control. In a main PLC station this module can control up to 512 I/O points.
MITSUBISHI
CPU unit
A1SJCPU


Program memory capacity: 8k. Input / output points: maximum 256 points.
MITSUBISHI
CPU unit
A1SJCPU-S3


Program memory capacity: 8k. Input / output points: maximum 256 points.
MITSUBISHI
CPU component
A1SJHCPU


I/O control method: refresh mode or direct mode. User program storage capacity: 8K step.
MITSUBISHI
Pulse capture module
A1SP60


The A1SP60 pulse capture module is a 16 point DC24V input module, Can be used as a general input module, Can also be used as a pulse capture module, Pulse capture function makes the input signal width in the sequence can be as short as 0.5ms, Once there is a pulse signal input, the state is memory, A1SP60 to ensure that the control process at least once again to control the state of the memory of the operation, Input can be set to 4 blocks, Each block can be set to a general function or pulse capture function.
MITSUBISHI
I/O bus monitoring module
A1SS91


A1SS91 is used to insert a fixed control program in front of the user program to monitor the specific Y output. Monitoring is carried out only when the CPU is in a state of running or stopping, and the monitoring failure is monitored in the suspended state.
MITSUBISHI
Analog timer module
A1ST60


A1ST60 analog timer module has 8 analog timers. Each timer can be set between 0.