MITSUBISHI Q68TD-G-H01 Product information and technical parameters:
Brand: MITSUBISHI
Name: Thermocouple type temperature input module
Model: Q68TD-G-H01
Input: 8 channels.
Thermocouple。
Conversion speed: 320ms/8 channel.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.

"Maximum control axis: 16 axis.
Connection mode with servo amplifier: IE CC-Link field network connection type.
The maximum distance between the drive units: 100m.
Operation cycle: 0.88ms, 1.77ms, 3.55ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points MITSUBISHI Q68TD-G-H01.
Color detecting set: 16 set.
Motion control into CC-LinkIE network Q68TD-G-H01
Positioning control, synchronization control and cam control can be easily carried out by the simple parameter setting and the starting of the sequential program.
QD77GF can be used as the main station of CC-LinkIE network.
Communication between 1 network implementation and servo amplifier, field device (remote I/O, sensor, etc MITSUBISHI Q68TD-G-H01. ).
Note 1:QD77G only the master station can use the bus shape, star. 1 networks can connect up to 104 units from the device.
Even the long distance wiring can be flexible.
The use of fiber optic cable, with high speed, high performance, high reliability of the servo system controller network.
In addition to the traditional positioning control, but also to support speed / torque control and synchronous control MITSUBISHI Q68TD-G-H01.
Use simple movement module setup tool",
Can easily perform positioning settings, monitoring and debugging, etc..
In addition, the data can be collected and displayed synchronously with the motion controller.
Support comprehensive, wiring flexible IE CC-Link field network.
This module can be used as the main station of IE CC-Link field network (equivalent to QJ71GF11-T2),
And still retains the function of simple motion module.
Therefore, flexible connection display (GOT), remote I/O, frequency converter and other equipment, flexible construction system. "Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time Q68TD-G-H01.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q68TD-G-H01.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.


...More relevant models >>>>