LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
Q1MEM-128SE | MITSUBISHI Memory card Q1MEM-128SE
MITSUBISHI Q1MEM-128SE Manual And Instructions
Q1MEM-128SE datasheetPDF datasheet

MITSUBISHI Q1MEM-128SE Product information and technical parameters:
Brand: MITSUBISHI
Name: Memory card
Model: Q1MEM-128SE
SRAM+E2PROM memory card.
RAM capacity: 64KB.
E2PROM capacity: 64KB.

I/O control method: refresh mode or direct mode.
User program storage capacity: 14K step.
I/O points: 512 points.
Memory capacity: bytes 64K.
ANSCPU has been updated to ANSHCPU, and it has the following advantages.
16 bit dedicated microprocessor.
Large capacity battery backup memory RAM.
Extended I/O control capability MITSUBISHI Q1MEM-128SE.
Dedicated CC-Link instruction.
Capacity for extended comment storage Q1MEM-128SE
PLC programming is a digital computing operation of the electronic system,
Designed for applications in industrial environments.
It uses programmable memory,
An instruction used to perform logical operations, sequence control, timing, counting and arithmetic operations in its internal storage,
And through the digital, analog input and output, control of various types of machinery or production process MITSUBISHI Q1MEM-128SE.
Programmable controller and related equipment,
Should be easy to make the industrial control system to form a whole, easy to expand the principle design of its functions. Program memory capacity 14K.
Input and output points to the maximum 512 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh MITSUBISHI Q1MEM-128SE.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage. Output type: transistor drain.
Output points: 16 points.
Load voltage: DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input commbination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order Q1MEM-128SE.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic Q1MEM-128SE.
And the control principle is decentralized, centralized and hybrid control three.