LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Catalog Download
MITSUBISHI Q1MEM-512SE datasheet PDF catalog Q1MEM-512SE PDF datasheet
Product model: Q1MEM-512SE
Name: Memory card
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Compact flash memory card.
Capacity: 8GB bytes. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module Q1MEM-512SE datasheet PDF catalog Q1MEM-512SE PDF datasheet Q1MEM-512SE
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q1MEM-512SE datasheet PDF catalog Q1MEM-512SE PDF datasheet.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q1MEM-512SE datasheet PDF catalog Q1MEM-512SE PDF datasheet.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. 8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change.
By detecting the transient peakk current at this time, the fault of the equipment can be diagnosed Q1MEM-512SE datasheet PDF catalog Q1MEM-512SE PDF datasheet.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q1MEM-512SE datasheet PDF catalog Q1MEM-512SE PDF datasheet.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
Memory card
Q1MEM-128S
MITSUBISHI Memory card Q1MEM-128S
SRAM memory card. RAM capacity: 128KB.
MITSUBISHI
Memory card
Q1MEM-64S
MITSUBISHI Memory card Q1MEM-64S
SRAM memory card. RAM capacity: 64KB.
MITSUBISHI
Memory card
Q1MEM-512S
MITSUBISHI Memory card Q1MEM-512S
SRAM memory card. RAM capacity: 512KB.
MITSUBISHI
Memory card
Q1MEM-128SE
MITSUBISHI Memory card Q1MEM-128SE
SRAM E2PROM memory card. RAM capacity: 6