LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
LJ61CL12 | MITSUBISHI CC-Link/LT master module LJ61CL12
MITSUBISHI LJ61CL12 Manual And Instructions
LJ61CL12 datasheetPDF datasheet

MITSUBISHI LJ61CL12 Product information and technical parameters:
Brand: MITSUBISHI
Name: CC-Link/LT master module
Model: LJ61CL12
CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed.
CC-Link/LT link scan time to reach the highest 1.2ms (2.5Mbps) at 64 stations,
Excellent response performance is achieved.
Can be selected according to the transmission distance 2.5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness.
Parameter settings that do not require any trouble.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.15A.
Weight: 0.12kg.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function MITSUBISHI LJ61CL12. Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K LJ61CL12
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control MITSUBISHI LJ61CL12.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement MITSUBISHI LJ61CL12.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized. Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Positive common end use. Convert connectors to e-CON.AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, tthe local power supply can be connected with the 4 wire type mixed use LJ61CL12.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply LJ61CL12.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.


...More relevant models >>>>