DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable.
Can also create suitable for small and medium sized factory wiring system.
Support remote I/O, analog quantity, temperature and humidity terminal, anti false operation terminal and other equipment.
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / output 512 points) of the I/O control.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km.
Can be used as a screw relay terminal.Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connectors to e-CON.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI LJ51AW12D2
LJ51AW12D2 AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points MITSUBISHI LJ51AW12D2.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours MITSUBISHI LJ51AW12D2.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, the local power supply can be connected with the 4 wire type mixed use.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power supply.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 32 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the innput / output of the switch signal,
Digital I/O modules are often called LJ51AW12D2.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch LJ51AW12D2.
Communication protocol is a standard Modbus protocol or custom protocol.