LH42C4PT1P-CM | MITSUBISHI Input / output mixed module LH42C4PT1P-CM
MITSUBISHI LH42C4PT1P-CM Manual And Instructions
LH42C4PT1P-CM datasheetPDF datasheet

MITSUBISHI LH42C4PT1P-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: Input / output mixed module
Model: LH42C4PT1P-CM
Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points).
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.

Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H module MITSUBISHI LH42C4PT1P-CM LH42C4PT1P-CM
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
In addition, the module can be used for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed MITSUBISHI LH42C4PT1P-CM. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have MITSUBISHI LH42C4PT1P-CM.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated from thee output of the programmable controller, the a/b/c contact relay, SSR, Tr output LH42C4PT1P-CM. Display characters: 16 x 4 character line width.
Display character: English letters and numbers (full / half), Katakana (full / half), hiragana (angle), ((angle), symbol Chinese characters (full / half) LH42C4PT1P-CM.
Language switch: Chinese / english.
Backlight display: green (normal), red (abnormal).
Weight 0.03kg.