Brand: MITSUBISHI
Go Back >> Product Catalogues
L60MD4-G-CM | MITSUBISHI Multiple input (voltage / current / temperature) module L60MD4-G-CM
MITSUBISHI L60MD4-G-CM Manual And Instructions
L60MD4-G-CM datasheetPDF datasheet

MITSUBISHI L60MD4-G-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: Multiple input (voltage / current / temperature) module
Model: L60MD4-G-CM
Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0.3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program.
No need to use ladder diagram conversion program, can reduce the programming time.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components.
Can be selected from low pass filter, high pass filter, medium pass filter.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened.

The terminal row is converted to e-CON.Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal.
Negative common end use. Control axis: maximum 16 axes.
Operation cycle: 0.88ms, 1.77ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation MITSUBISHI L60MD4-G-CM.
Color signal: 4 points.
Color detecting set: 16 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control L60MD4-G-CM
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program MITSUBISHI L60MD4-G-CM.
Let motion control more simple. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm MITSUBISHI L60MD4-G-CM.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth conntinuous analog output L60MD4-G-CM.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L60MD4-G-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.