LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
L06CPU-CM | MITSUBISHI cpu module L06CPU-CM
MITSUBISHI L06CPU-CM Manual And Instructions
L06CPU-CM datasheetPDF datasheet
L06CPU-CM Common InstructionsProgramming Manual
L06CPU-CM Special InstructionsProgramming Manual
L06CPU-CM Application FunctionsProgramming Manual
L06CPU-CM Common InstructionsProgramming Manual
L06CPU-CM Structured Text(ST)PROGRAMMING Guide Book
L06CPU-CM Structured TextProgramming Manual
L06CPU-CM MELSAP-LProgramming Manual
L06CPU-CM Structured TextProgramming Guide
L06CPU-CM PID Control InstructionsProgramming Manual
L06CPU-CM Special InstructionsProgramming Manual
L06CPU-CM Common InstructionsProgramming Manual
L06CPU-CM Application FunctionsProgramming Manual
L06CPU-CM ApplicationUser's Manual
L06CPU-CM Structured TextProgramming Manual

MITSUBISHI L06CPU-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L06CPU-CM
"Universal output function: leakage type.
Program capacity: 60K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "

Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50 MITSUBISHI L06CPU-CM.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0 L06CPU-CM3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program.
No need to use ladder diagram conversion program, can reduce the programming time MITSUBISHI L06CPU-CM.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components.
Can be selected from low pass filter, high pass filter, medium pass filter MITSUBISHI L06CPU-CM.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters off the programming tool L06CPU-CM.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L06CPU-CM.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "


...More relevant models >>>>