MITSUBISHI L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual
Product model: L06CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time L06CPU-CM To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control). Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display L06CPU-CM MELSAP-L Manual L06CPU-CM Programming Manual.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type