LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TB1L16XYN | MITSUBISHI Conversion module FA-TB1L16XYN
MITSUBISHI FA-TB1L16XYN Manual And Instructions
FA-TB1L16XYN datasheetPDF datasheet

MITSUBISHI FA-TB1L16XYN Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB1L16XYN
Can be used as a screw relay terminal. Positive common end use.

Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring MITSUBISHI FA-TB1L16XYN.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm FA-TB1L16XYN
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement MITSUBISHI FA-TB1L16XYN.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period MITSUBISHI FA-TB1L16XYN.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Convert connectors to e-CON.Number of input channels: 8ch.
Input voltage: DC - 10 ~ 10V.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal deetection function of the input signal which is outside the range of the set range FA-TB1L16XYN.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter rannge extension
Range of scalable input range FA-TB1L16XYN.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.


...More relevant models >>>>