FA-TB16XYPN | MITSUBISHI Conversion module FA-TB16XYPN
MITSUBISHI FA-TB16XYPN Manual And Instructions
FA-TB16XYPN datasheetPDF datasheet

MITSUBISHI FA-TB16XYPN Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB16XYPN
Can be used as a screw relay terminal.

Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal MITSUBISHI FA-TB16XYPN.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI FA-TB16XYPN FA-TB16XYPN The connector is converted to a screw relay terminal.DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k MITSUBISHI FA-TB16XYPN.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision conntrol FA-TB16XYPN.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized FA-TB16XYPN.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.


...More relevant models >>>>