LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
A1SX41 | MITSUBISHI DC leakage type input module A1SX41
MITSUBISHI A1SX41 Manual And Instructions
A1SX41 datasheetPDF datasheet
A1SX41 User's Manual

MITSUBISHI A1SX41 Product information and technical parameters:
Brand: MITSUBISHI
Name: DC leakage type input module
Model: A1SX41
Type of input: DC leakage.
Input points: 32 points.
Input voltage: 12/24.
Input current: 3/7mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and complex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced.

AnS, QnAS bus connection, the reader to write program 1 channel connection.Capable of continuous thermocouple or platinum temperature measurement.
In addition, the temperature measurement range can be set with the use of the temperature.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of MITSUBISHI A1SX41 A1SX41
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI A1SX41.
This phenomenon is called the I/O delay time effect. SRAM memory card MITSUBISHI A1SX41.
RAM capacity: 64KB. Data format: ASCII.
Data bits: 7.
A1SJ71UC24-R2-S2 and A1SJ71UC24-R4-S2 allow the Ans series PLC to be connected to the MODBUS network,
As the network from the station, and in accordance with the instructions of the main station of the CPU Ans user storage area for data reading / writing.
In addition to supporting the MODBUS protocol, these components also support the standard dedicated communication protocol for A1SJ71UC24 components.
This feature makes the main station of the data acquisition and control with more flexibility.
Support MODBUS slave station protocol.
Supports 1 to 21 function code.
Two transmission modes: RTU or ASCII. 1 slots; no power supply; used to install large PLC series AnS module.
Base plate of AnS series PLC.
QA1S series PLC 1 slot main substrate.
AnS series of modules can be installed. Interface: RS422/485
Transmission distance: 500 meterrs
A1SJ71UC24-R2/R4/PR computer communication components can be relied on external intelligent devices such as computers and PLC for communication, the components are as follows:
Full / half duplex transmission,
4 special communication protoccols,
No protocol and bidirectional mode,
Protocol selection switch function,
The optional baud rate, the highest 19 A1SX41 A1SX41. 2K,
Since the echo diagnostic test,


...More relevant models >>>>