Bus connection.
Program 2 channel connection.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations
MR-J3ENCBL10M-A2-H Motor series: super low inertia, medium power.
Rated output power: 2.0kw.
Rated speed: 3000r/min.
Whether to take the brake: No.
Shaft keyway: (open slot).
Protection level: IP65 (IP67).
Features: ultra low inertia is suitable for high frequency operation.
Application example: ultra high frequency transmission machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring.
MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 1.0kw.
Interface type: SSCNET type III fiber communication.
Power specification: three phase AC400V.
High speed serial communication between the SSCNET and the servo amplifier by using the fastest up to 0.44ms communication cycle,
A fully synchronous control system can be constructed.
It is only necessary to insert the special optical fiber into the joint to form SSCNET III network, which greatly reduces the wiring work and reduces the possibility of false wiring.
Due to the adoption of the optical fiber communication, the anti noise ability can be greatly improved and the long distance wiring of 50 meters (maximum 800 meters x 16 axes) can be realized.
A servo amplifier to meet the full closed loop control function MR-J3-B-RJ006.
Suitable for mechanical servo optimization and adjustment!
More advanced optimization adjustment function and control function to maximize mechanical properties. I/O slots: 8 slots.
Could you install the power module.
Outline dimension: 420*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board.
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection.
MR-J3ENCBL10M-A2-H Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3ENCBL10M-A2-H&select=5