Max input / output points: 40 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 16 points.
Output type: Transistor (source).
Power consumption (W): 32.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x75.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed
FX3UC-96MT/DSS
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control. Function: high performance and low price in the middle end model.
Picture size: 8.4 inches.
Resolution: VGA.
Display: TFT color.
Panel color: black.
Power type: DC24V.
Middle end model of high performance and low price.
GT25 standard supports SD memory card and standard equipped with Ethernet, RS-232, RS-422/485, host/device USB interface.
Even in the log, script, alarm, soft component data transmission, such as high load processing period, but also to achieve smooth operation of the screen.
Connect GOT front USB interface and computer,
Can be through the FA, the GOT machine programming, start and adjust the operation,
Save the trouble of opening the control cabinet and changing the cable.
1, USB interface: device USB machine (Mini-B USB)
Can connect to the computer to transfer data.
2, USB interface: host USB (USB-A)
USB data can be transmitted through the USB memory or read log data, such as the GOT data, but also can be connected to the use of the mouse, keyboard.
3, the extension of the interface
Communication module and optional module can be installed.
4, Ethernet interface
Up to 4 different manufacturers can be connected at the same time
FA machine.
5, RS-232 interface
Can connect all kinds of FA machine, bar code reader, serial printer.
6, RS-422/485 interface
Can be connected to a variety of FA machines, bar code reader.
7, SD memory card slot
Can save alarm and log data, such as a large number of data.
FX3UC-96MT/DSS Operation manual/Instructions/Model selection sample download link: