For video input (NTSC/PAL) 4ch/ analog 1ch RGB input.
Applicable model: GT27. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 15KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%)
A2CPU
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Protective film for 5.7 inch screen.
Scrub (frame: white), 5.
Applicable model: GT15. Motor series: medium inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 2.0kw.
Rated speed: 1000rpm.
With the brake: without.
Shaft end: straight shaft.
The structure of the AC servo motor stator is basically similar to the capacitor split phase single-phase induction motor.
The stator is provided with two positions of 90 degrees of mutual difference of the winding, one is the excitation winding Rf, it is always connected to the AC voltage Uf;
The other is to control the winding L, which is connected to the control signal voltage Uc.
So the AC servo motor, also known as the two servo motor. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DC5V output 2A DC24V/.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
A2CPU Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A2CPU&select=5