FA-TB16XY Market price | FA-TB16XY Introduction
MITSUBISHI FA-TB16XY
CC-Link-AnywireASLINK bridge module.Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative FA-TB16XY
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 1 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DAC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Coaxial data communication line function.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
FA-TB16XY Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FA-TB16XY&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Terminal module
FA-TH16X24D31L
MITSUBISHI Terminal module FA-TH16X24D31L
Can e isolated to otain DC24/48/100V,
MITSUBISHI
Conversion module
FA-LEB16XY-D
MITSUBISHI Conversion module FA-LEB16XY-D
The terminal row is converted to e-CON.
MITSUBISHI
Conversion module
FA-TB16XYPN
MITSUBISHI Conversion module FA-TB16XYPN
Can e used as a screw relay terminal.
MITSUBISHI
Terminal module
FA-TH16YRAC20S
MITSUBISHI Terminal module FA-TH16YRAC20S
Can e isolated from the output of the p