MITSUBISHI A0J2-E56DS datasheet PDF catalog A0J2-E56DS PDF datasheet
Product model: A0J2-E56DS
Name: DC input / silicon controlled output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input points: 32 points.
Input voltage and current: 120V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
36 point terminal station A0J2-E56DS datasheet PDF catalog A0J2-E56DS PDF datasheet.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A0J2-E56DS datasheet PDF catalog A0J2-E56DS PDF datasheet A0J2-E56DS
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A0J2-E56DS datasheet PDF catalog A0J2-E56DS PDF datasheet.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. AC input points: 16 points.
Input voltage and current: AC100 ~ 10mA, 120V.
Response time: 25ms.
16 point /1 a public side.
Bidirectional thyristor output points: 12 points.
Output voltage and current: AC100 ~ 120V, 0.6A/1 point, 2.4A/1 public end.
Response time: 0.5Hz1ms.
8 point /1 a public end, 4 point /1 a public end.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet ee-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system A0J2-E56DS datasheet PDF catalog A0J2-E56DS PDF datasheet.
At the same time, tthe use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information A0J2-E56DS datasheet PDF catalog A0J2-E56DS PDF datasheet.
Related products
MITSUBISHI
AC input / relay output module
A0J2-E56AR
MITSUBISHI AC input / relay output module A0J2-E56AR
Input points: 32 points. Input voltage a
MITSUBISHI
Connecting cable
A0J2-C06
MITSUBISHI Connecting cable A0J2-C06
Horizontally placed cale. Length: 550mm
MITSUBISHI
Computer connection module
A0J2-C214-S1
MITSUBISHI Computer connection module A0J2-C214-S1
RS-232C 1 channel, RS-422 1 channel. Tra