Input / output points: 4096 points.
Number of input and output elements: 8192.
Program capacity: 500 K step.
Processing speed: 0.0095 s.
Program memory capacity: 2000 KB.
Support USB and network.
Support installed memory card.
Providing high speed communication between multiple CPU.
Shorten the fixed scan interrupt time, high precision device Q7BAT-SET Manual Q7BAT-SET Instruction manual.
The minimum interval of the fixed period interrupt program is reduced to 100 s
Q7BAT-SET
The high speed signal can be accurately obtained, which makes the contribution to the higher precision of the device.
High speed and high precision machine control by multi CPU.
By parallel processing of the linear and multi CPU high-speed communication (cycle 0.88ms) of the parallel control program, the high speed control Q7BAT-SET Manual Q7BAT-SET Instruction manual.
Multi CPU high speed communication cycle and motion control synchronization, so it can achieve the maximization of computing efficiency.
In addition, the latest movement control CPU in performance is 2 times the previous model,
To ensure high speed and high accuracy of the machine control.Battery replacement.
Initial voltage 3.0V.
Base of large capacity battery Q7BAT-SET Manual Q7BAT-SET Instruction manual.
Current capacity: 5000mAh.
Service life: 5 years.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop caan reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q7BAT-SET Manual Q7BAT-SET Instruction manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q7BAT-SET Manual Q7BAT-SET Instruction manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.