LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI Q00JCPU-S8-SET MELSAP-L Manual Q00JCPU-S8-SET Programming Manual
Product model: Q00JCPU-S8-SET
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs Q00JCPU-S8-SET MELSAP-L Manual Q00JCPU-S8-SET Programming Manual.
High speed communication capable of communicating with 1Gbps Q00JCPU-S8-SET
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX Q00JCPU-S8-SET MELSAP-L Manual Q00JCPU-S8-SET Programming Manual.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q00JCPU-S8-SET MELSAP-L Manual Q00JCPU-S8-SET Programming Manual. 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Output points: 4 points (select the source type + drain type), 2 points (when selecting the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the compoonents in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q00JCPU-S8-SET MELSAP-L Manual Q00JCPU-S8-SET Programming Manual Q00JCPU-S8-SET MELSAP-L Manual Q00JCPU-S8-SET Programming Manual.
Related products
MITSUBISHI
CPU with base plate
Q00JCPU
MITSUBISHI CPU with base plate Q00JCPU
Program capacity: 8K step. Input / outpu
MITSUBISHI
Small points with substrate CPU
Q00JCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-S8-SET
Input / output points: 256 points. Progr
MITSUBISHI
Small points with substrate CPU
Q00UJCPU-S8-SET
MITSUBISHI Small points with substrate CPU Q00UJCPU-S8-SET
Upgrade payments. Input / output points:
MITSUBISHI
Small points with substrate CPU
Q00JCPU-SET
MITSUBISHI Small points with substrate CPU Q00JCPU-SET
Input / output points: 256 points. Progr