Battery replacement.
Initial voltage 3.0V.
Service life: 5 years.Q series of basic conversion module, A series of additional basic unit connection adapter unit.
Suitable for: A5 - B/A6 - B.Master / local station sharing.
Corresponding Ver2 CC-Link.
I/O control in the first class of open field network module Q12DCCPU-V Structured Text Manual Q12DCCPU-V Programming Manual.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information)
Q12DCCPU-V
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time Q12DCCPU-V Structured Text Manual Q12DCCPU-V Programming Manual.
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module.8 axes, open collector output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control Q12DCCPU-V Structured Text Manual Q12DCCPU-V Programming Manual.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parammeters, procedures, etc Q12DCCPU-V Structured Text Manual Q12DCCPU-V Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q12DCCPU-V Structured Text Manual Q12DCCPU-V Programming Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.