LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
R12CCPU-V | MITSUBISHI C language controller module R12CCPU-V
MITSUBISHI R12CCPU-V Manual And Instructions
R12CCPU-V datasheetPDF datasheet

MITSUBISHI R12CCPU-V Product information and technical parameters:
Brand: MITSUBISHI
Name: C language controller module
Model: R12CCPU-V
Memory capacity: 256MB.
As one of the specific features of the iQ-R CPU series MELSEC module, the new C language controller module is added.
C language ARM developed a multi-core controller can perform multiple programs simultaneously based on.
In addition, both the robustness and timing of the C language controller can also be used as a substitute for computer / computer platform.
Moreover, the C language controller adopts a non fan structure, and does not raise dust, and is most suitable for use in a clean environment such as a micro chip factory.
Play iQ-R MELSEC series of high performance, flexible, strong characteristics, can be used in a variety of industrial applications to achieve automation.
Can be simple to use 3 kinds of tool software.
C language controller has been installed in a variety of drivers embedded real-time OS. Various modules can be easily accessed through a special function,
No need to develop the driver and install new OS, through a special function to access a variety of modules,
Can be simple to deploy, reduced cost of development.
You can use CW Workbench and CW Configurator (software) (setting and monitoring tools) and CW-Sim (simulation tool VxWorks.),
Provide strong support for C language program development.
Can be easily programmed, no restrictions on the microprocessor.
By using the C language controller module specific function (CCPU function), MELSEC communication function (MD function),
Can easily access the C language controller module, I/O module, intelligent function module, network module, programmable controller CPU and sports CPU, etc.,
Create an application that uses a programmable controller device.
Configurator CW can be used for parameter setting, diagnosis and monitoring.
Using Configurator CW,
The iQ-R/Q MELSEC series module (network module, intelligent function module, input and output module, etc.) can be easily set, diagnosis, monitor and test by the C language controller module.
The operation of Configurator CW is similar to that of iQ-R MELSEC programming software Works3 GX.

The input power supply voltage: AC100 ~ 240V.
Input frequency: 50/60Hz plus or minus 5%.
Input maximum apparent power: 160VA.
Maximum input power: -.
Rated output current (DC5V): 9A.
Rated output current (DC24V): -.
IQ-R MELSEC series consists of CPU module, power module, substrate module, input and output module, intelligent function module and so on MITSUBISHI R12CCPU-V.
For the entire system, the substrate module can be expanded to 7 levels, up to 64 modules can be installed,
Therefore, large scale system can be constructed R12CCPU-V In addition, by using the RQ extended substrate module,
The sea can also effectively use the MELSEC-Q series of modules of the asset. ""Input points: 16 points.
Rated input voltage and frequency: DC24V MITSUBISHI R12CCPU-V.
Rated input current: TYP 7.0mA.
Response time: 0.1 ~ 70ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs MITSUBISHI R12CCPU-V.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "Analog input channel number: 8CH.
Cold end compensation precision.
Available thermocouple: -.
Available temperature resistance: Pt100, JPt100, Ni100, Pt50.
Resolution: 0.1.
Conversion speed: 10ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector.
output
The temperature measurement value (16 bit''signed binary): 2000 ~ 8500.
Zoom value (16 bit with symbol binary).
No program can perform conversion operations, scaling
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data. The analog quantity input data can be stored and maintaineed before and after the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data R12CCPU-V. Such as motor testing equipment used in this function.
Control instructions from a programmablee controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time R12CCPU-V.


...More relevant models >>>>