16 axes.
Connect SSCNET III.
Control unit: pulse.
Location data: 32 data / axis.
Ideal solution for simple multi axis positioning.
A variety of functions, such as positioning control, constant velocity control, and other positioning control systems.
The multi axis system is most suitable for simple positioning control Q06UDHCPU Structured Text Manual Q06UDHCPU Programming Manual.
Ideal selection for high speed linear positioning control in multi axis system
Q06UDHCPU
Linear interpolation operation with up to 4 axes can be carried out.
With the electronic gear, gap compensation, absolute position system, such as basic positioning function. Input points: servo external signal 32 points, 8 axis.
Input mode: source / drain type.
Input and output points: 32 points Q06UDHCPU Structured Text Manual Q06UDHCPU Programming Manual.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports Q06UDHCPU Structured Text Manual Q06UDHCPU Programming Manual.
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the change of the specified control data without any omission.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.8 slots.
Requires 1 power modules.
Used to install the old section of the large A series PLC module.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis pphenomena, i Q06UDHCPU Structured Text Manual Q06UDHCPU Programming Manual. e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation Q06UDHCPU Structured Text Manual Q06UDHCPU Programming Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.