MITSUBISHI Q12PHCPU SFC Manual Q12PHCPU Programming Manual
Product model: Q12PHCPU
Name: CPU
Brand: MITSUBISHI
Sort: SFC Programming Manual
File language: English
Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment Q12PHCPU SFC Manual Q12PHCPU Programming Manual Q12PHCPU
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program Q12PHCPU SFC Manual Q12PHCPU Programming Manual . Alarm monitoring is divided into 2 stages of attention alarm and danger alarm.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
In addition, Works2 GX (1.90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).Input and output points: 512 points Q12PHCPU SFC Manual Q12PHCPU Programming Manual .
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment. "1ch RS-232.
1ch RS-422/485.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line.
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC protocol, through tthe external devices (PC, monitors, etc Q12PHCPU SFC Manual Q12PHCPU Programming Manual . ) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the pprogrammable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices Q12PHCPU SFC Manual Q12PHCPU Programming Manual . "
Related products
MITSUBISHI
Process CPU
Q06PHCPU
MITSUBISHI Process CPU Q06PHCPU
Program capacity: 60 K step. Input / out
MITSUBISHI
High performance CPU
Q02HCPU
MITSUBISHI High performance CPU Q02HCPU
Program capacity: 28K step. Input / outp
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching
MITSUBISHI
Process CPU
Q25PHCPU
MITSUBISHI Process CPU Q25PHCPU
Program capacity: 252 K step. Input / ou