LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI L06CPU-P MELSAP-L Manual L06CPU-P Programming Manual
Product model: L06CPU-P
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
CC-Link master / local station.
Transmission speed: 10Mbps.
Remote input / output: 8192 points.
Remote register: 2048 words.
Link points in Ver.2.0 CC-Link master station.
Using CC-Link to connect with multiple devices.
Rich device using open network CC-Link,
System can be constructed according to the control requirements L06CPU-P MELSAP-L Manual L06CPU-P Programming Manual.
Support Ver.2.0 CC-Link,
So it can be effectively used in the field of large capacity data communication L06CPU-P
No need to set the transmission speed of the local station
Automatic tracking function of transmission speed
When used as a local station, the transmission speed of the master station can be automatically tracked,
Do not need to set up in the local station.
The transmission speed of the operation can be confirmed by the positive LED of the module L06CPU-P MELSAP-L Manual L06CPU-P Programming Manual. Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start L06CPU-P MELSAP-L Manual L06CPU-P Programming Manual.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog output.
Waveform output funnction
Equipped with the industry''s first waveform output function L06CPU-P MELSAP-L Manual L06CPU-P Programming Manual.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L06CPU-P MELSAP-L Manual L06CPU-P Programming Manual.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.
Related products
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type.
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type.
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type