Input / output type: transistor output (source).
Output points: 8 points.
Input and output points: 8 points.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms FX3U-16MT/ESS MODBUS Serial Communication Edition Manual FX3U-16MT/ESS USER'S MANUAL
FX3U-16MT/ESS
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with external serial devices.
FX2N extension module FX3U-16MT/ESS MODBUS Serial Communication Edition Manual FX3U-16MT/ESS USER'S MANUAL.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit FX3U-16MT/ESS MODBUS Serial Communication Edition Manual FX3U-16MT/ESS USER'S MANUAL. Power: 22kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. The operation, monitoring, parameter modification and other operations can be carried out by computer or PLC.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 5.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrrical FX3U-16MT/ESS MODBUS Serial Communication Edition Manual FX3U-16MT/ESS USER'S MANUAL.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FX3U-16MT/ESS MODBUS Serial Communication Edition Manual FX3U-16MT/ESS USER'S MANUAL.