LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FX3U-48MT/ESS Basic & Applied Instructions Edition Manual FX3U-48MT/ESS PROGRAMMING MANUAL
Product model: FX3U-48MT/ESS
Name: PLC
Brand: MITSUBISHI
Sort: Basic & Applied Instructions Edition PROGRAMMING MANUAL
File language: English
Total points: 32 points.
Input points: 16 points.
Input mode: DC24V (drain type).
Output points: 16 points.
Output form: Transistor (drain type).
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 FX3U-48MT/ESS Basic & Applied Instructions Edition Manual FX3U-48MT/ESS PROGRAMMING MANUAL FX3U-48MT/ESS
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 45KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment FX3U-48MT/ESS Basic & Applied Instructions Edition Manual FX3U-48MT/ESS PROGRAMMING MANUAL.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on FX3U-48MT/ESS Basic & Applied Instructions Edition Manual FX3U-48MT/ESS PROGRAMMING MANUAL. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 2.2KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, vvalve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure FX3U-48MT/ESS Basic & Applied Instructions Edition Manual FX3U-48MT/ESS PROGRAMMING MANUAL FX3U-48MT/ESS Basic & Applied Instructions Edition Manual FX3U-48MT/ESS PROGRAMMING MANUAL.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.
Related products
MITSUBISHI
PLC
FX3G-60MT/ESS
MITSUBISHI PLC FX3G-60MT/ESS
Input points: 36 points. Output points:
MITSUBISHI
PLC
FX3S-30MT/ESS-2AD
MITSUBISHI PLC FX3S-30MT/ESS-2AD
Built in analog input models. Input / ou
MITSUBISHI
Adapter for high speed input
FX3U-4HSX-ADP
MITSUBISHI Adapter for high speed input FX3U-4HSX-ADP
High speed input adapter FX3U- - racy -