LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A970GOT-TBA-CH Hardware Manual A970GOT-TBA-CH User's Manual
Product model: A970GOT-TBA-CH
Name: touch screen
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.2.
Internal storage RAM memory capacity: 64K
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program A970GOT-TBA-CH Hardware Manual A970GOT-TBA-CH User's Manual A970GOT-TBA-CH
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment A970GOT-TBA-CH Hardware Manual A970GOT-TBA-CH User's Manual. . Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input AC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
User program storage capacity: it is a measure of how much the user application can store the number of indicators A970GOT-TBA-CH Hardware Manual A970GOT-TBA-CH User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuitt outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnected from the load A970GOT-TBA-CH Hardware Manual A970GOT-TBA-CH User's Manual A970GOT-TBA-CH Hardware Manual A970GOT-TBA-CH User's Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.