LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A4UCPU Dedicated Instructions Manual A4UCPU Programming Manual
Product model: A4UCPU
Name: PLC
Brand: MITSUBISHI
Sort: Dedicated Instructions Programming Manual
File language: English
Input points: 32 points.
Input voltage: AC100 ~ 120V.
Current: 6mA.
Response time: 30ms.
16 points / a common end.
50 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation A4UCPU Dedicated Instructions Manual A4UCPU Programming Manual.
Read only memory A4UCPU Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference A4UCPU Dedicated Instructions Manual A4UCPU Programming Manual. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A4UCPU Dedicated Instructions Manual A4UCPU Programming Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay. Storage capacity: 16MB.
Applicable models: A985 (-V) /A975/A970/A960GOT (-B). Input type: DC input, positive common end.
Input points: 8 pointss A4UCPU Dedicated Instructions Manual A4UCPU Programming Manual.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CONN type A4UCPU Dedicated Instructions Manual A4UCPU Programming Manual.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.
Related products
MITSUBISHI
Motion controller
Q170MCPU
MITSUBISHI Motion controller Q170MCPU
Axis of control: 16. Compact Q170MCPU in
MITSUBISHI
CPU unit
A2SCPU
MITSUBISHI CPU unit A2SCPU
Program memory capacity 14K. Input and o
MITSUBISHI
CPU unit
Q4ACPU
MITSUBISHI CPU unit Q4ACPU
Input and output points: 4096 points. In
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Num