MITSUBISHI Q10UDEHCPU Multiple CPU System Manual Q10UDEHCPU User's Manual
Product model: Q10UDEHCPU
Name: CPU
Brand: MITSUBISHI
Sort: Multiple CPU System User's Manual
File language: English
DC5V DC current consumption: 0.23A.
Number of I/O modules can be installed: 8.
Program capacity: 8K step.
Input / output points: 256 points.
Number of input and output elements: 2048.
Power +8 tank bottom plate of the CPU.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function Q10UDEHCPU Multiple CPU System Manual Q10UDEHCPU User's Manual.
Can be set up to 32 characters of the file password Q10UDEHCPU
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights Q10UDEHCPU Multiple CPU System Manual Q10UDEHCPU User's Manual.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.For 32 point I/O. 0.5 square mm (AWG20).Program capacity: 8K step.
Input / output points: 1024 points.
Number of input and output elements: 2048.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function Q10UDEHCPU Multiple CPU System Manual Q10UDEHCPU User's Manual.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.Compact flash memory card.
Capacity: 4GB bytes. Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
With external power supply function.
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data update is improved.
The transmission delay time iss shortened, and the synchronous waiting time of the application can be shortened Q10UDEHCPU Multiple CPU System Manual Q10UDEHCPU User's Manual.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish thee network can handle large capacity data Q10UDEHCPU Multiple CPU System Manual Q10UDEHCPU User's Manual.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station.
Related products
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Num