MITSUBISHI A173UHCPU (SV13/22)(REAL MODE) Manual A173UHCPU Programming Manual
Product model: A173UHCPU
Name: MOTION CONTROLLER
Brand: MITSUBISHI
Sort: (SV13/22)(REAL MODE) Programming Manual
File language: English
QnA/ACPU bus connection.
2 joint.
Applicable models: A985 (-V) /975/970/960/956 (W) GOT. Cable length: 35 meters.
For QCPU and GOT (need A9GT-QCNB) connection.
For the connection between GOT and GOT. Type of input: DC source.
Input points: 16 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row A173UHCPU (SV13/22)(REAL MODE) Manual A173UHCPU Programming Manual.
Common common point: 16 A173UHCPU
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions.
Each step represents a control function, represented by the box A173UHCPU (SV13/22)(REAL MODE) Manual A173UHCPU Programming Manual.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time.
Used in the system of the size of the school, procedures for more complex occasions A173UHCPU (SV13/22)(REAL MODE) Manual A173UHCPU Programming Manual.
Sequence function flow chart programming language features: to function as the main line, in accordance with the functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the complicated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced. Output points: 32 points.
Voltage: DC5/12/24V.
OFF leakage current: 0.1mA.
Output type: bidirectional thyristor output (type sink).
Response time: 10ms.
8 points / a common end.
50 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performancee to price ratio, a reasonable choice of PLC A173UHCPU (SV13/22)(REAL MODE) Manual A173UHCPU Programming Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A173UHCPU (SV13/22)(REAL MODE) Manual A173UHCPU Programming Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
High performance CPU
Q06HCPU
MITSUBISHI High performance CPU Q06HCPU
Program capacity: 60 K step. Input / out
MITSUBISHI
Moving CPU unit
A173UHCPU
MITSUBISHI Moving CPU unit A173UHCPU
CPU:A3UCPU PLC is the same. PLC program
MITSUBISHI
Process CPU
Q25PRHCPU
MITSUBISHI Process CPU Q25PRHCPU
Program capacity: 252 K step. Input / ou
MITSUBISHI
Motion CPU module
Q172HCPU
MITSUBISHI Motion CPU module Q172HCPU
Control axis: maximum 8 axes. Teaching o