LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A1SJCPU-S3 Fundamentals Manual A1SJCPU-S3 Programming Manual
Product model: A1SJCPU-S3
Name: PLC
Brand: MITSUBISHI
Sort: Fundamentals Programming Manual
File language: English
26 point line conversion adapter 1 line type 16 input CC-Link unit installation special connection conversion adapterOutput points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
38 point terminal station.
With heat protection A1SJCPU-S3 Fundamentals Manual A1SJCPU-S3 Programming Manual.
With the surge absorber.
With short circuit protection A1SJCPU-S3
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A1SJCPU-S3 Fundamentals Manual A1SJCPU-S3 Programming Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A1SJCPU-S3 Fundamentals Manual A1SJCPU-S3 Programming Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 2 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of prograam simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A1SJCPU-S3 Fundamentals Manual A1SJCPU-S3 Programming Manual A1SJCPU-S3 Fundamentals Manual A1SJCPU-S3 Programming Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
Moving CPU unit
A73CPU-S3
MITSUBISHI Moving CPU unit A73CPU-S3
Special multi axis positioning controlle
MITSUBISHI
CPU unit
A1SJCPU
MITSUBISHI CPU unit A1SJCPU
Program memory capacity: 8k. Input / out
MITSUBISHI
CPU unit
A1SJCPU-S3
MITSUBISHI CPU unit A1SJCPU-S3
Program memory capacity: 8k. Input / out