LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product catalogues
MITSUBISHI
Melsecnet interface module
A1SJ71AP21


PLC station distance: 1Km. Cable type: QSI-200/250.
MITSUBISHI
Melsecnet interface module
A1SJ71AP21GE


PLC station distance: 2Km. Cable type: GI-62.5/125.
MITSUBISHI
Melsecnet interface module
A1SJ71AP21-S3


PLC station distance: 2Km. Cable type: GI-50/125.
MITSUBISHI
Melsecnet interface module
A1SJ71AR21


PLC station distance: 500M. Cable type: coaxial cable.
MITSUBISHI
Modular
A1SJ71AS92


The main unit of the AS-i system The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. This phenomenon is called the I/O delay time effect.
MITSUBISHI
Melsecnet interface module
A1SJ71AT21B


Cable type: twisted pair cable. The function of the MELSECNET interface module is to connect the main CPU PLC to the MELSECNET data communication system.
MITSUBISHI
Modular
A1SJ71B62-S3


Signal transmission device B/NET interface device for power distribution control equipment The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on. This phenomenon is called the I/O delay time effect.
MITSUBISHI
Network module
A1SJ71BR11


3C-2V/5C-2V coaxial cable between the single bus PC network (control station / common station) / remote I/O network (remote master). The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it, Lag time, this is the time constant of the input circuit, The time constant of the output circuit, the arrangement of the user statement and the use of the instruction, The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.