Master station module supporting AnyWireASLINK system.
Connecting sensor and programmable controller.
Free configuration of sensors, control of 512 points of the input and output.
The AnyWireASLINK transmission line (2 lines) can be used for communication to supply power for the sensor, and the sensor can also be conveniently added.
Can through the project software GXWorks2 batch management sensor shedding detection and from the station module settings, etc.,
2 channel.
Input: DC4~20mA (connecting two wire transmitter); DC0~20mA.
Output (resolution): 0~4000. 0~12000.
Conversion speed: 10ms/ channel.
40 pin connector.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark MITSUBISHI QJ51AW12AL
QJ51AW12AL
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier MITSUBISHI QJ51AW12AL.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.RS-422/485.
2 channel MITSUBISHI QJ51AW12AL.
Transmission speed: 2 channels.
Total 230.4kbps.
Corresponding Configurator-SC Version2 GX.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC protocol, through the external devices (PC, monitors, etc.) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) witth the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a publiic telephone line QJ51AW12AL QJ51AW12AL.
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.