LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
Q62HLC | MITSUBISHI Loop control module Q62HLC
MITSUBISHI Q62HLC Manual And Instructions
Q62HLC datasheetPDF datasheet
Q62HLC datasheetPDF datasheet
Q62HLC HardwareUser's Manual
Q62HLC User's Manual

MITSUBISHI Q62HLC Product information and technical parameters:
Brand: MITSUBISHI
Name: Loop control module
Model: Q62HLC
Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station.

RS232 cable for connecting cables and 3M, CPU.PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station).
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1 MITSUBISHI Q62HLC. 2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q62HLC5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) MITSUBISHI Q62HLC.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.8 axes MITSUBISHI Q62HLC.
Connect SSCNET III.
Control unit: pulse.
Location data: 32 data / axis.
Ideal solution for simple multi axis positioning.
A variety of functions, such as positioning control, constant velocity control, and other positioning control systems.
The multi axis system is most suitable for simple positioning control.
Ideal selection for high speed linear positioning control in multi axis system.
Linear interpolation operation with up to 4 axes can be carried out.
With the electronic gear, gap compensation, absolute position system, such as basic positioning function. Battery replacement.
Initial voltage 3.0V.
Replace large capacity battery module with cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mmInput voltage range: AC100-240V.
Output voltage: DC5V/24V.
Output power: 0.6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
Too prevent the loss of the program and the parameters due to forgetting to replace the battery Q62HLC.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q62HLC.
The next time the power is turned on, the backup data will be automatically restored.


...More relevant models >>>>