LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
Q06CCPU-V-H01 | MITSUBISHI C language CPU Q06CCPU-V-H01
MITSUBISHI Q06CCPU-V-H01 Manual And Instructions
Q06CCPU-V-H01 datasheetPDF datasheet
Q06CCPU-V-H01 datasheetPDF datasheet
Q06CCPU-V-H01 Special InstructionsStrctured Programming Manual
Q06CCPU-V-H01 Application FunctionsStrctured Programming Manual
Q06CCPU-V-H01 Common InstructionsStrctured Programming Manual
Q06CCPU-V-H01 FundamentalsStrctured Programming Manual
Q06CCPU-V-H01 User's Manual
Q06CCPU-V-H01 Multiple CPU SystemUser's Manual
Q06CCPU-V-H01 Function Explanation, Program FundamentalsUser's Manual
Q06CCPU-V-H01 Hardware Design, Maintenance and InspectionUser's Manual
Q06CCPU-V-H01 Structured TextProgramming Manual
Q06CCPU-V-H01 MELSAP-LProgramming Manual
Q06CCPU-V-H01 SFCProgramming Manual
Q06CCPU-V-H01 PID Control InstructionsProgramming Manual
Q06CCPU-V-H01 Common Instructions 1/2Programming Manual

MITSUBISHI Q06CCPU-V-H01 Product information and technical parameters:
Brand: MITSUBISHI
Name: C language CPU
Model: Q06CCPU-V-H01
Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Automatically transfer the record file to the FTP server,
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.

FL-net (OPCN-2) Ver.1.00 interface.
10BASE5 use.E81WH4W, QE83WH4W special transformer.
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information MITSUBISHI Q06CCPU-V-H01 Q06CCPU-V-H01
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment MITSUBISHI Q06CCPU-V-H01.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1 MITSUBISHI Q06CCPU-V-H01. 90U and higher) can be used to easily set parameters.Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
QJ61CL12 can be used as the main station of CC-Link/LT.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at thhe same time Q06CCPU-V-H01.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q06CCPU-V-H01.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.


...More relevant models >>>>