LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
Q00JCPU-S8 | MITSUBISHI CPU with base plate Q00JCPU-S8
MITSUBISHI Q00JCPU-S8 Manual And Instructions
Q00JCPU-S8 datasheetPDF datasheet
Q00JCPU-S8 datasheetPDF datasheet
Q00JCPU-S8 Special InstructionsStrctured Programming Manual
Q00JCPU-S8 Application FunctionsStrctured Programming Manual
Q00JCPU-S8 Common InstructionsStrctured Programming Manual
Q00JCPU-S8 FundamentalsStrctured Programming Manual
Q00JCPU-S8 Multiple CPU SystemUser's Manual
Q00JCPU-S8 Function Explanation, Program FundamentalsUser's Manual
Q00JCPU-S8 Hardware Design, Maintenance and InspectionUser's Manual
Q00JCPU-S8 Structured TextProgramming Manual
Q00JCPU-S8 MELSAP-LProgramming Manual
Q00JCPU-S8 SFCProgramming Manual
Q00JCPU-S8 PID Control InstructionsProgramming Manual
Q00JCPU-S8 Common Instructions 1/2Programming Manual
Q00JCPU-S8 Structured Text(ST)Programming Guide Book

MITSUBISHI Q00JCPU-S8 Product information and technical parameters:
Brand: MITSUBISHI
Name: CPU with base plate
Model: Q00JCPU-S8
DC5V DC current consumption: 0.23A.
Number of I/O modules can be installed: 8.
Program capacity: 8K step.
Input / output points: 256 points.
Number of input and output elements: 2048.
Power +8 tank bottom plate of the CPU.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.

MODBUS/TCP Master slave station.
10BASE-T/100BASE-TX.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment MITSUBISHI Q00JCPU-S8.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device Q00JCPU-S8
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment MITSUBISHI Q00JCPU-S8. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI Q00JCPU-S8.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion moldingg machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q00JCPU-S8.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q00JCPU-S8.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.


...More relevant models >>>>