Industrial level switch hub.
NZ2EHF-T8 supports 10Mbps/100Mbps transfer rate.
With MDI/MDI-X Auto function, automatic negotiation function, etc..
The use of automatic power regulation function, can make up to a reduction of about 80%*2.
Do not use the cooling fan, but can be in a larger ambient temperature range (0 ~ 50 degrees C) normal operation.
By using simple and easy loading and unloading DIN guide rail fixing mechanism, all kinds of installation can be easily carried out.
Type: 18 point terminal.
Input points: 16 points.
Rated voltage: DC24V.
Input response time: 0 ~ 70ms.
Input format: common terminal / negative public end sharing.
External connection: 1 wire.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices MITSUBISHI NZ2EHF-T8.
Can be connected to the expansion module, more convenient to expand the input and output points
NZ2EHF-T8
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station MITSUBISHI NZ2EHF-T8. Type: 18 point terminal.
Input / output mode: Thermocouple Input, transistor output, channel insulation.
Number of stations: 1 stops.
Number of channels: 4 channels.
Sampling period is 250ms/4 channel. Use 1 sets of temperature control module,
Can achieve standard control (heating, cooling) and heating cooling control.
This module has the functions of heating up, maximum current suppression, self diagnosis and so on MITSUBISHI NZ2EHF-T8.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. CC-Link IE field network AnyWireASLINK bridge module.
AnyWireASLINK products can be seamlessly connected to the IE CC-Link field network. Wireless LAN adapter.
Implementtation of the plant LAN (Ethernet) wireless, but also more flexible to increase production lines, change the layout NZ2EHF-T8.
There is no need for wiring, so the cost of wiring can be greatly reduced.
Simply connect the wireless LAN adapter, you caan easily achieve the existing FA wireless devices NZ2EHF-T8.
Meet the latest safety standards WPA2/WPA, can be separated from the outside of the illegal access.