Open collector output.
Axis of control: 4.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.
Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI LD75P4-CM MITSUBISHI LD75P4-CM
LD75P4-CM Can be used as a screw relay terminal.Enter points: 64 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: 64 points).
External wiring connection: 40 pin connector two MITSUBISHI LD75P4-CM.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on. Input and output (DC/ differential).
Input points: 12 points (DC5V/DC24V/ differential universal).
Pulse input speed: the highest pulse/s 8M (2MHz).
Output points: 8 points (DC5V ~ DC24V) 6 points (differential).
Pulse output speed: the highest pulse/s 8M (2MHz).
High speed and stable input / output response
The high speed response can be achieved without the CPU module''s operation and bus performance,
Stable input and output response through hardware processing.
LD40PD01 is equipped with an external input and output interface and FPGA,
Therefore, high speed control can be realized without the influence of the scanning time of the CPU module and the bus performance (the input and output response time of the s instruction is realized).
Can achieve stable input and output response (proccessing time of the deviation of the ns level) LD75P4-CM.
Through the intuitive tools for FPGA settings.
In the FPGA design process can be omitted in the past must be designed to deal with (HDL description, logic synthesis and time verification),
Reeduce working hours LD75P4-CM. After receiving the product can be used immediately to verify the use of special tools, can significantly shorten the design time.