LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
LD62D-CM | MITSUBISHI High speed counter module LD62D-CM
MITSUBISHI LD62D-CM Manual And Instructions
LD62D-CM datasheetPDF datasheet

MITSUBISHI LD62D-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: High speed counter module
Model: LD62D-CM
Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.

Output points: 8 points (independent of all points).
Rated output voltage: DC24V/AC240V.
Rated open and close current: 2A/1 point.
Public side mode: no public side (all points of independent contact).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal MITSUBISHI LD62D-CM.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called LD62D-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch MITSUBISHI LD62D-CM.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be used as a screw relay terminal. Negative common end useDC5V internal consumption current: 0.08A.
Weight: 0.13kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control MITSUBISHI LD62D-CM.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module. Output points: 32 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called LD62D-CM.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch LD62D-CM.
Communication protocol is a standard Modbus protocol or custom protocol.


...More relevant models >>>>