LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
L6EC-ET-CM | MITSUBISHI End cap with ERR terminal L6EC-ET-CM
MITSUBISHI L6EC-ET-CM Manual And Instructions
L6EC-ET-CM datasheetPDF datasheet

MITSUBISHI L6EC-ET-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: End cap with ERR terminal
Model: L6EC-ET-CM
Error output.
Rated open and close voltage, current: DC24V, 0.5A.
Minimum open and close load: DC5V, 1mA.
Response time (OFF, ON): 10ms below.
Response time (ON, OFF): 12ms below.
Life (Mechanical): more than 20 million times.
Life (Electrical) rated open and close voltage, current more than 100 thousand times.
Suitable for wire specifications: 0.3 ~ 2 square mm (AWG22 ~ 14) (twisted pair / single line).
External wiring connection mode: spring clip terminal.
DC5V internal consumption current: 0.06A.
Weight: 0.11kg.

Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. RS-232.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication MITSUBISHI L6EC-ET-CM L6EC-ET-CM
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication MITSUBISHI L6EC-ET-CM.
The content of the communication protocol that can be created in the list,
Can also be simply edited. Output points: 64 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points) MITSUBISHI L6EC-ET-CM.
External wiring connection: 40 pin connector two.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool L6EC-ET-CM.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L6EC-ET-CM.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "


...More relevant models >>>>
Related download