LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FX2N-16EYR | MITSUBISHI Relay output module FX2N-16EYR
MITSUBISHI FX2N-16EYR Manual And Instructions
FX2N-16EYR datasheetPDF datasheet

MITSUBISHI FX2N-16EYR Product information and technical parameters:
Brand: MITSUBISHI
Name: Relay output module
Model: FX2N-16EYR
Total input and output points: 16 points.
Output points: 16 points.
Output type: relay output.
FX Series in the compact body built in superior performance, and strive to operate simple.
In addition, rich options can meet the various needs of customers.
In the virtual factory will be rich in the function of a part of the introduction.
It is easy to control the analog quantity of the application.
Can be extended to all models in the FX series analog devices.
Function extension board, special adapter without programming can be used for communication.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit.

Function: terminal row input.
Input points: 16 points.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC.
Weight: 0.15KG.
FX2NC expansion module can be directly connected to the FX1NC, FX2NC, PLC FX3UC on the expansion of the input and output.
Do not need to connect the cable and so on, therefore can carry on the compact expansion MITSUBISHI FX2N-16EYR. Input and output form: DC input, relay output FX2N-16EYR
Input points: 4 points.
Output points: 8 points.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms MITSUBISHI FX2N-16EYR.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with external serial devices.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect MITSUBISHI FX2N-16EYR.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
The number of connection points depends on the basic unit and the expansion unit. Enter 16 points or 16 points.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (sinktype).
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password prootection, using a eight digit password to protect your program FX2N-16EYR.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FX2N-16EYR.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).


...More relevant models >>>>