LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FR-HAL-H280K | MITSUBISHI AC reactor FR-HAL-H280K
MITSUBISHI FR-HAL-H280K Manual And Instructions
FR-HAL-H280K datasheetPDF datasheet

MITSUBISHI FR-HAL-H280K Product information and technical parameters:
Brand: MITSUBISHI
Name: AC reactor
Model: FR-HAL-H280K
Power: 280kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)

MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.4KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy MITSUBISHI FR-HAL-H280K FR-HAL-H280K
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure MITSUBISHI FR-HAL-H280K.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements. Power: 11kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed MITSUBISHI FR-HAL-H280K. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reacttor FR-HAL-H280K.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Can use the encoder to perform vector control.
Combined use of the position detector (PLG) with the position of the main shaft of the working maachine,
Can be carried out on the position of the spindle stop (directional) control FR-HAL-H280K.
The speed is kept constant through feedback motor rotation speed.


...More relevant models >>>>