Voltage level: three phase 400V.
Applicable motor capacity: 450kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power.
"MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 0.4kw.
SLD converter rated current: 2.3A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product MITSUBISHI FR-CC2-H450K-60.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption
FR-CC2-H450K-60
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program MITSUBISHI FR-CC2-H450K-60.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements.
The control of each machine can be done separately by the frequency converter, and the control of the dispersion is also carried out MITSUBISHI FR-CC2-H450K-60.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "Power: 15kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the mootor capacity to choose FR-CC2-H450K-60. ) Power: 75kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connectedd without built-in brake transistor inverter FR-CC2-H450K-60.
Three types of discharge resistors are available.
Please select according to the required braking torque.