FR-A820-2.2K-1(FR-A820-00167-2-60) | MITSUBISHI Three phase 200V grade frequency converter FR-A820-2.2K-1(FR-A820-00167-2-60)
MITSUBISHI FR-A820-2.2K-1(FR-A820-00167-2-60) Manual And Instructions
FR-A820-2.2K-1(FR-A820-00167-2-60) datasheetPDF datasheet

MITSUBISHI FR-A820-2.2K-1(FR-A820-00167-2-60) Product information and technical parameters:
Brand: MITSUBISHI
Name: Three phase 200V grade frequency converter
Model: FR-A820-2.2K-1(FR-A820-00167-2-60)
MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.

Power: 0.75kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor MITSUBISHI FR-A820-2.2K-1(FR-A820-00167-2-60). (the IP55 series has a built-in DC reactor FR-A820-2.2K-1(FR-A820-00167-2-60))
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Power: 18.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity MITSUBISHI FR-A820-2.2K-1(FR-A820-00167-2-60).
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI FR-A820-2.2K-1(FR-A820-00167-2-60). ) Voltage level: three phase 400V.
Applicable motor capacity: 315kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 15KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FR-A820-2.2K-1(FR-A820-00167-2-60).
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FR-A820-2.2K-1(FR-A820-00167-2-60).