LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TH16YTR20S | MITSUBISHI Terminal module FA-TH16YTR20S
MITSUBISHI FA-TH16YTR20S Manual And Instructions
FA-TH16YTR20S datasheetPDF datasheet

MITSUBISHI FA-TH16YTR20S Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YTR20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Convert connectors to e-CON.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function MITSUBISHI FA-TH16YTR20S FA-TH16YTR20S
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range MITSUBISHI FA-TH16YTR20S.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range MITSUBISHI FA-TH16YTR20S.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected. Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Can be used as a screw relay terminal.Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the inputt / output of the switch signal,
Digital I/O modules are often called FA-TH16YTR20S.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch FA-TH16YTR20S.
Communication protocol is a standard Modbus protocol or custom protocol.


...More relevant models >>>>