Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.
Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (source).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) MITSUBISHI FA-TH16YSR11S
FA-TH16YSR11S
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged MITSUBISHI FA-TH16YSR11S.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible MITSUBISHI FA-TH16YSR11S.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 88CH, bit 8CH data can be displayed in real time FA-TH16YSR11S.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display FA-TH16YSR11S.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.